Welcome to Excellence Integrity Management - Empowering Professionals Globally.
Storage tanks: read in the feed

Inspection · 2 min read

Routine inspection rounds

The cheapest inspection is a trained person walking round.

Operators and site staff walk every tank regularly and look for leaks, stains, distortion, settlement, damaged coating, blocked drains, vent problems and anything unusual. Most serious problems are first noticed on a routine round, so what people record and report matters.

  • Routine rounds are done by trained site personnel, frequently, and are visual.
  • They look for leaks, wet ground, stains, distorted plates, settlement, coating damage and fitting problems.
  • Good rounds follow a checklist, record what was seen and escalate anything unusual.
  • A routine round does not replace the formal inspection by a qualified inspector.

Not every inspection needs an instrument. A large share of tank problems are first seen by an operator on a walk-round, and the standards recognise this by requiring regular routine in-service inspections in addition to the formal inspections by a qualified inspector.

On a routine round the person looks at the things that can be seen from the ground and the stairway. Are there leaks, stains or wet patches at the shell, at nozzles, at the foot of the tank or in the bund? Is the coating in good order? Are plates distorted or bulged? Does the tank seem to be leaning, or is there a gap at the foundation? Are the drains, vents, gauges and ladders in working order? Is the roof of a floating tank sitting normally?

The value of a round depends on discipline. A checklist keeps it consistent, a record shows trends, and a clear rule on what to report, and to whom, means that a small leak does not become a large one. Staff need to know why they are looking, not just what to tick.

Routine rounds complement formal external and internal inspections. They cover the gap between those events, when a defect may appear and grow. The frequency is set by the owner's programme and the code, and the common expectation is that it is regular and frequent, as often as monthly.

Good practice

  • Use the same route and checklist each time so changes stand out.
  • Photograph and date anything abnormal, with a reference point for location.

Avoid

  • Do not wait for the formal inspection to report a leak or a new distortion.
  • Do not record "no change" without actually looking.

In the field

Ask who does the rounds and what training they have had. A short briefing on what to look for often improves reporting more than any new instrument.

Routine in-service inspection:
a regular visual check of a tank in operation by site staff.

Based on: API 653, API 575. A summary for learning. The standard and your site procedures govern.

Preparing for an exam? Take it with you.

The EIM app has study notes, practice questions with explanations, timed mock tests and your progress, on your phone. Free to download. Android first, iPhone to follow.

Get it on Google Play