A roof that rides the liquid up and down, open to the sky.

An external floating roof sits directly on the liquid and rises and falls with the level. A seal closes the gap between the roof and the shell. With almost no vapour space, evaporation and fire risk are lower. The roof has to drain rain water and stay level.

  • The roof floats on the product, so there is almost no vapour space and far less evaporation.
  • A rim seal closes the gap between the roof edge and the shell; there may be a primary and a secondary seal.
  • Pontoons or a double deck give the roof its buoyancy.
  • A drain system carries rain water off the roof, and a rolling ladder and guide pole let people and the roof move safely.

An external floating roof tank has no fixed roof. The roof lies on the liquid and moves with it, so there is almost no vapour space. That cuts evaporation losses and removes most of the flammable vapour that a fixed roof would trap, which is why these tanks are common for crude oil and light products in large sizes.

The roof is kept afloat by pontoons around its edge, or by a double deck that is buoyant throughout. A flexible seal fills the gap between the roof and the shell. The gap has to stay small enough to limit vapour loss and protect the seal, but large enough that the roof never binds, because shell shape is never perfectly round.

Because the roof is open to the sky, it has to deal with rain. A drain system carries rain water over or through the product to the outside. A rolling ladder lets people reach the roof at any level, and a guide pole or similar device keeps the roof from rotating.

Typical findings on inspection are worn or torn seals, uneven gaps, leaking or flooded pontoons, blocked or leaking drains, corrosion on the deck, and signs the roof is catching on the shell. Several of these point to something other than the roof itself, such as an out-of-round shell or an uneven foundation, so a good inspector follows the symptom back to its cause.

Good practice

  • Check seal condition and the gap around the roof at several levels.
  • Look at the roof drain, the pontoons and the stored rain water after heavy rain.

Avoid

  • Do not let rain water pond on the roof beyond its design allowance.
  • Do not ignore a roof that is tilted, jammed or rubbing the shell.

In the field

A roof that sticks as the level moves is a warning about shell distortion or settlement. Note exactly where it catches, and at what level.

Pontoon:
a sealed buoyant compartment that keeps the roof afloat.
Rim seal:
the flexible seal in the gap between the roof and the shell.

Based on: API 650, API 653, API 575. A summary for learning. The standard and your site procedures govern.