Welcome to Excellence Integrity Management - Empowering Professionals Globally.

API 570 Piping Classes and Inspection Intervals

API 570 piping classes and inspection intervals explained: Class 1 to 4, thickness and external visual maximums, half remaining life, and injection points.

By Syed Hasan5 Nov 20263 min read

API 570 Piping Classes and Inspection Intervals

This is the first post in our API 570 cluster. Unlike vessels and tanks, piping is sorted into classes by the consequence of a failure, and each class has its own maximum intervals for thickness measurement and external visual inspection. Knowing the classes and how the intervals interact with remaining life is the foundation of piping inspection planning.

Short answer: API 570 puts piping into four classes. Class 1, the highest consequence, has maximum intervals of 5 years for both thickness measurement and external visual inspection. Class 2: 10 years thickness, 5 years visual. Class 3: 10 and 10. Class 4: at the owner's option. Injection point circuits have a 3-year thickness maximum. In every case, the thickness interval also cannot exceed half the remaining life, and RBI can set intervals instead.

The classes

  • Class 1: services with the highest potential for an immediate emergency if a leak occurs, for example flammable services that can vaporise rapidly and ignite, and highly toxic services such as HF or H2S-rich streams.
  • Class 2: most other process hydrocarbon and many chemical services.
  • Class 3: lower-consequence services, such as flammable liquids that do not vaporise significantly and many product lines.
  • Class 4: essentially non-hazardous services, where inspection is at the owner's option.

Half the remaining life

The class sets a ceiling, not a target. API 570 also limits the thickness inspection interval to half the remaining life calculated from the corrosion rate. For a corroding line, half-life usually governs.

Illustrative. The shorter of the two governs.
Illustrative. The shorter of the two governs.

Worked example

A Class 2 circuit has a measured thickness of 0.180 in, a required (governing) thickness of 0.110 in and a corrosion rate of 0.010 in/yr. Remaining life is (0.180 − 0.110) / 0.010 = 7 years. Half of that is 3.5 years, well inside the Class 2 cap of 10 years, so the next thickness inspection is due in 3.5 years. The external visual inspection is due within the 5-year Class 2 maximum. See piping minimum thickness for where the 0.110 in comes from.

Special cases

  • Injection point circuits: maximum 3 years for thickness measurement; see injection point circuits.
  • Soil-to-air interfaces: inspected by class, with attention to coating and corrosion at the interface.
  • RBI: a risk-based assessment can set intervals in place of the class defaults, under API 570's RBI provisions.
  • Pressure-relieving devices: have their own intervals; see PSV test intervals.

Learn more with EIM

EIM is an independent training provider; API certifies piping inspectors. Our API 570 exam page explains the certification, its eligibility and the codebooks. The EIM Calculator includes corrosion rate, remaining life, MAWP and retirement thickness tools. For operators, EIM's inspection services include in-service piping inspection and CML rationalisation.

Frequently asked questions

What are the API 570 piping classes?

Four classes by consequence of failure: Class 1 highest, Class 2 most process services, Class 3 lower consequence, and Class 4 essentially non-hazardous.

What is the maximum thickness interval for Class 1 piping?

5 years, or half the remaining life if that is shorter.

What are the Class 2 intervals?

10 years maximum for thickness measurement and 5 years for external visual inspection.

How often must injection points be inspected?

Injection point circuits have a 3-year maximum for thickness measurement.

Can RBI replace the class intervals?

Yes. API 570 allows intervals to be set by a risk-based inspection assessment.

Sources

Exam preparation

Preparing for API 570?

Practise with exam-style questions, timed mocks and study notes. 1,841 questions in the bank.

  • API 570 inspection intervals
  • API 570 piping class
  • API 570 class 1 class 2 class 3
  • Piping inspection frequency
  • API 570 half remaining life
  • +1
Share

Related Certifications

Certifications covered in this article. Each guide has the exam format, eligibility route and a practice question bank.