Inspection intervals at a glance
The main interval rules in API 510, 570 and 653, including the half-life and RCA/4N rules.
Follows API 510, 570, 653 terminology
| Inspection | Interval |
|---|---|
| Internal or on-stream | The lesser of half the remaining life or 10 years. If the remaining life is under 4 years, up to the full remaining life, with a maximum of 2 years. |
| External visual | At least every 5 years, or at the internal or on-stream interval, whichever is less. |
| Pressure-relief devices | Typically 5 years in process service; up to 10 years in clean, non-fouling, non-corrosive service. |
| Class | Thickness measurement | External visual |
|---|---|---|
| Class 1 (highest risk) | 5 years | 5 years |
| Class 2 | 10 years | 5 years |
| Class 3 (lowest risk) | 10 years | 10 years |
| Injection points | 3 years |
The thickness interval is also limited to half the remaining life if that is shorter than the table value.
| Inspection | Interval |
|---|---|
| Routine in-service inspection (owner or operator) | At least monthly. |
| External inspection by an authorized inspector | At least every 5 years, or RCA / (4N) years, whichever is less. |
RCA is the difference between the measured shell thickness and the minimum required thickness, in mils. N is the shell corrosion rate in mils per year.
- Most intervals are the lesser of a fixed maximum and half the remaining life. Work the remaining life out with the corrosion rate calculator.
A summary for learning and quick recall. The current edition of each code governs, and so does your owner-user inspection programme. Check the edition before you rely on a number.
Preparing for API 510, 570 or 653?Preparing for an exam? Take it with you.
The EIM app has study notes, practice questions with explanations, timed mock tests and your progress, on your phone. Free to download. Android first, iPhone to follow.